Fluid Components International’s twin alarm FLT93 Series circulate change supplies an early warning alert to the potential of dry running situations, cavitation and different pump points that can lead to emergency shutdowns and dear maintenance.
The FLT93 Series circulate switch reliably monitors the circulate and temperature of liquids, gases, and slurries. – Image: Fluid Components International
FCI’s FLT93 Series move swap reliably displays the move and temperature of liquids, gases, and slurries. It is designed for pump wet/dry detection, where sudden, sudden reductions in media flow charges can depart pumps vulnerable to over-heating situations that shutdown process traces and require troubleshooting and fixing. เกจวัดแรงดันสูญญากาศ rated instrument is intended for heavy-duty, potentially hazardous process business environments and comes with a complete listing of global safety approvals.
It has a no shifting parts design and presents a robust scheme for pump protection with its twin alarm capability. With Alarm 1, the swap detects a low circulate state of affairs wherever between zero.01 and 3 ft per second FPS (0.003–0.9 m per second MPS). This low circulate alarm is a pre-warning signal for the control system or operator who can then decide to keep the pump running or to shut it down.
If an Alarm 2 occurs as a result of the feed line to the pump is operating dry, this may be an emergency signal to shut down the pump instantly as a end result of the bearings now see gas as a substitute of a liquid as a warmth switch media. In such conditions, the temperature of the bearings could rise very quick. Using a circulate swap prevents permanent harm to the pump’s bearings.